Client: Lafarge
Roofing Technical Centre
Technology: Dust
Control System
MECHON were commissioned to provide a complete
new dust control system in the client’s clay preparation
area.
An existing system was in place, however it was found to
be non-compliant with the CoSHH Regulations 2004, due to
high Workplace Exposure Limits (WEL’s) and low ductwork
conveying velocities.
MECHON paid particular attention to the design of the hoods
on all preparation equipment, including mills, crushers,
sieves, and weigh scales. The intricate design of the hoods
resulted in efficient extraction from all points, reducing
the need for a large ductwork system and filtration unit.
Electric actuator controlled dampers were positioned in
various branches along the system: enabling the operator
to select an extraction point corresponding to the equipment
in use. This technology once again reduced overall capital
and running costs.
The dust-laden air was conveyed to a MECHON RJE-30-5.5 filtration
unit. This unit utilises reverse-jet cleaning technology
to ensure consistent extraction rates, and extended element
life.
<--